The AUSTROMAT D4press: cleverly uses the atmospheric air pressure - the atmosphere's natural force - rather than compressed air to press items reliably. This patented process even allows the pressing force to be controlled in 5 stages to enable muffles with a diameter of up to 70 mm and a height of 90 mm to be pressed reliably. The combination furnace has 200 firing programs available for individual programming. The integrated program manager allows clear and comfortable administration of the firing programs. The entire firing process with the firing number, program name and probable remaining time is displayed graphically or in a table on the color screen. The automated self-check by the 32-bit electronics of the AUSTROMAT D series ensures perfect firing monitoring and maximum reliability. The heating, holding or cooling phases preset in standard mode are freely programmable in professional mode.
DEKEMA Autodry: Simulates object temperature measurement and automatically regulates the distance from the firing chamber with the stepless, vibration-free lift for precise drying and cooling phases.
Easy programming and operation: The menu guides you through a fixed program sequence with freely-settable value ranges.
| Professional Mode | Range | Interval | Unit |
| Dry temperature (Autodry) | 100 to 200 | 1 | °C |
| Start temperature/ preheating temperature | 100 to 700 | 1 | °C |
| Drying time | 00:00 to 09:59 | 00:01 | min:s |
| Closed time | 00:00 to 09:59 | 00:01 | min:s |
| Preheating time | 00:00 to 09:59 | 00:01 | min:s |
| Vacuum level | 0 to 100 | 10 | % |
| Temperature increase | 2 to 99 or max. | 1 | °C/min |
| Final temperature/ firing temperature | 100 to 1200 | 1 | °C |
| Holding period with/without vacuum | 00:00 to 99:59 | 00:01 | min:s |
| Temperature rise/drop 2 | 2 to 99 or max. | 1 | °C/min |
| End/firing/cooling/relaxation temperature 2 | 100 to 1200 | 1 | °C |
| Holding period with/without vacuum 2 | 00:00 to 99:59 | 00:01 | min:s |
| Temperature rise/drop 3 | 2 to 99 or max. | 1 | °C/min |
| End/firing/cooling/relaxation temperature 3 | 100 to 1200 | 1 | °C |
| Holding period with/without vacuum 3 | 00:00 to 99:59 | 00:01 | min:s |
| Cooling temperature | 100 to 1200 | 1 | °C |
| Cooling time | 00:00 to 99:59 | 00:01 | min:s |
| Relaxation temperature | 100 to 1200 | 1 | °C |
| Relaxation time | 00:00 to 99:59 | 00:01 | min:s |
| Standard Mode | Range | Interval | Unit |
| Dry temperature (Autodry) | 100 to 200 | 1 | °C |
| Start temperature/ preheating temperature | 100 to 700 | 1 | °C |
| Drying time | 00:00 to 09:59 | 00:01 | min:s |
| Closed time | 00:00 to 09:59 | 00:01 | min:s |
| Preheating time | 00:00 to 09:59 | 00:01 | min:s |
| Vacuum level | 0 to 100 | 10 | % |
| Temperature increase | 2 to 99 or max. | 1 | °C/min |
| Final temperature/ firing temperature | 100 to 1200 | 1 | °C |
| Holding period without vacuum | 00:00 to 99:59 | 00:01 | min:s |
| Cooling temperature | 90% of end temperature | ||
| Cooling time | 00:00 to 09:59 | 00:01 | min:s |
| Relaxation temperature | 65% of end temperature | ||
| Relaxation time | 00:00 to 09:59 | 00:01 | min:s |
| Press Mode | Range | Interval | Unit |
| Start temperature/ preheating temperature | 100 to 900 | 1 | °C |
| Final temperatur/ press temperature | 100 to 1200 | 1 | °C |
| Press time | 00:00 to 99:59 | 00:01 | min:s |
| Press level | 1 to 5 | 1 | 180 to 280 N |
Pressing: Items may be pressed with varying force ranging from 180 - 280 N. In this case the force is transmitted to the press muffle slowly and evenly from above via one plunger.
Changing the running program: The firing parameters can be changed with the press of a key while the current program is running and saved if desired.
Automatic self-test: Internal test routines seamlessly monitor the temperature and vacuum while the program is running.
Check program: An automatic diagnosis routine is integrated for all system components to determine the service intervals.
Setup functions: Setup functions enable user-defined adaptation of a wide variety of options such as display contrast, record printout, saving data on the computer, general code, temperature calibration, acoustic signal, date and time, ID, Data transfer, update fix programs, language, screen saver, °C/°F changeover, check programme, battery change, diagnosis data, printing programs, seal test, service functions for maintenance, longterm readiness Software update via memory modules: Plug-in modules save the firing programs and simplify updating the device software.
Software update via memory modules: Plug-in modules save the firing programs and simplify updating the device software.
Scope of delivery: AUSTROMAT D4press ceramic furnace, vacuum pump, firing table, press table, tweezers, soft module, operating instructions, RS232 computer interface, individualizedpaint job and memo module upon request.
Technical data: 220-240 V, 110-120 V or 95-105 V, 50-60 Hz, max. 1450 W (incl. pump), 623 mm x 380 mm x 340 mm (HxWxD), 17.5 kg (without pump).