AUSTROMAT D4: 200 firing programs are available for individual programming. The integrated program manager allows clear and comfortable administration of the firing programs. The entire firing process with the firing number, program name and probable remaining time is displayed graphically or in a table on the color screen. The automated self-check by the 32-bit electronics of the AUSTROMAT D series ensures perfect firing monitoring and maximum reliability. The heating, holding or cooling phases preset in standard mode are freely programmable in professional mode.

DEKEMA AUTODRY: Simulates object temperature measurement and automatically regulates the distance from the firing chamber with the stepless, vibration-free lift for precise drying and cooling phases.

Easy programming and operation: The menu guides you through a fixed program sequence with freely-settable value ranges.

Professional Mode Range Interval Unit
Dry temperature (AUTODRY) 100 to 200 1 °C
Start temperature/ preheating temperature 100 to 700 1 °C
Drying time 00:00 to 09:59 00:01 min:s
Closed time 00:00 to 09:59 00:01 min:s
Preheating time 00:00 to 09:59 00:01 min:s
Vacuum level 0 to 100 10 %
Temperature increase 2 to 99 or max. 1 °C/min
Final temperature/ firing temperature 100 to 1200 1 °C
Holding period with/without vacuum 00:00 to 99:59 00:01 min:s
Temperature rise/drop 2 2 to 99 or max. 1 °C/min
End/firing/cooling/relaxation temperature 2 100 to 1200 1 °C
Holding period with/without vacuum 2 00:00 to 99:59 00:01 min:s
Temperature rise/drop 3 2 to 99 or max. 1 °C/min
End/firing/cooling/relaxation temperature 3 100 to 1200 1 °C
Holding period with/without vacuum 3 00:00 to 99:59 00:01 min:s
Cooling temperature 100 to 1200 1 °C
Cooling time 00:00 to 99:59 00:01 min:s
Relaxation temperature 100 to 1200 1 °C
Relaxation time 00:00 to 99:59 00:01 min:s
Standard Mode Range Interval Unit
Dry temperature (AUTODRY) 100 to 200 1 °C
Start temperature/ preheating temperature 100 to 700 1 °C
Drying time 00:00 to 09:59 00:01 min:s
Closed time 00:00 to 09:59 00:01 min:s
Preheating time 00:00 to 09:59 00:01 min:s
Vacuum level 0 to 100 10 %
Temperature increase 2 to 99 or max. 1 °C/min
Final temperature/ firing temperature 100 to 1200 1 °C
Holding period without vacuum 00:00 to 99:59 00:01 min:s
Cooling temperature 90% of end temperature
Cooling time 00:00 to 09:59 00:01 min:s
Relaxation temperature 65% of end temperature
Relaxation time 00:00 to 09:59 00:01 min:s

Changing the running program: The firing parameters can be changed with the press of a key while the current program is running and saved if desired.

Automatic self-test: Internal test routines seamlessly monitor the temperature and vacuum while the program is running.

Check program: An automatic diagnosis routine is integrated for all system components to determine the service intervals.

Setup functions: Setup functions enable user-defined adaptation of a wide variety of options such as display contrast, record printout, saving data on the computer, general code, temperature calibration, acoustic signal, date and time, ID, Data transfer, update fix programs, language, screen saver, °C/°F changeover, check programme, battery change, diagnosis data, printing programs, seal test, service functions for maintenance

Software update via memory modules: Plug-in modules save the firing programs and simplify updating the device software.

Scope of delivery: AUSTROMAT D4 ceramic oven, vacuum pump, firing table, oven tweezers, memo module, operating instructions, RS232 computer interface, individualized paint job and soft module upon request.

Technical data: 220-240 V, 110-120 V or 95-105 V, 50-60 Hz, max. 1450 W (incl. pump), 612 mm x 380 mm x 340 mm (HxWxD), 17.5 kg (without pump).